Energy cables > 1KV


There are more than 1.000 reasons for Waskönig+Walter. We call them "Cables".

There are more than 1.000 reasons for Waskönig+Walter. We call them "Cables".

Looking for a medium-voltage power cable for the large new housing estate at the outskirts of Copenhagen? A control cable with 61 cores for the Netherlands? A high-voltage cable in utmost lenghts in order to avoid jointing? At Waskönig+Walter this would not pose a problem.

With our range of more than 1,000 different products, not only can we offer you standard varieties in line with the market, but also individual products, in accordance with your specific requirements.

Ranging from underground cables to the cabling of industrial high-performance machines, right up to smart home services, Waskönig+Walter ensures the perfect connection - in interiors, outdoors, in the ground, on or underneath plaster, in dry or wet rooms, as well as in brickwork or concrete.

And, as special wishes are commonplace in professional use, we are also able to comply with your specific requirements, right from the very first contact. The results of this are tailor-made products and services: on- time delivery, individual cutting to comply with the lengths you require and a great number of other services in the field of logistics.

Class name:
Power cable >= 1 kV, for permanent installation
Conductor material:
Aluminium
Nominal cross section conductor:
Shape of conductor:
Round
Insulation:
XLPE (VPE)
Laminated sheath:
No
Inner semi-conducting layer:
Ja
Armouring:
No
Specification material outer sheath:
Polyethylene (PE)
Conductive coating:
No
Longitudinal water blocking screen:
Ja
Halogen free (acc. EN 60754-1/2):
Ja
Low smoke (acc. EN 61034-2):
No
Minimum bending radius:
15 x Außen-Ø
Max. conductor temperature:
90 °C
Nominal voltage U0:
18 kV
max. short circuit temperature:
250 °C
Type:
NA2XS(F)2Y 30kV
Conductor surface:
Bare
Conductor category:
Class 2 = stranded
Number of cores:
1 Stck
Core identification:
None
Fibre optic elements:
No
Outer semi-conducting layer:
Ja
Material outer sheath:
Polyolefin
Colour outer sheath:
Black
Longitudinal water blocking conductors:
No
Reaction-to-fire class according to EN 13501-6:
Fca
Flame retardant:
No
Outer diameter approx.:
Min. permitted bending radius, stationary application/permanent installation:
Permitted cable outer temperature during assembling/handling:
-20 70 °C
Nominal voltage U:
30 kV
Permitted cable outer temperature after assembling without vibration:
-40 70 °C
0 / Compare
Datasheet
Declaration of Performance
All filters
Ohne Schnittlängen
Products: 11 / 11
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X1000 RM/35 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X120 RM/16 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X150 RM/25 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X150 RM/25 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X185 RM/25 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X240 RM/25 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X400 RM/35 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X50 RM/16 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X500 RM/35 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X70 RM/16 30kV SW
Type
NA2XS(F)2Y 30kV
Individual length
Cut length
Name
NA2XS(F)2Y 1X95 RM/16 30kV SW